Connectivity

Command Ack Timeout

Configure Command Ack Timeout in HPzenAi Smart. Detects when a device does not confirm a command.

What it does

Notify when a device does not confirm a command.

Detects when a device does not confirm a command. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryConnectivity
Works with
GatewaysWater MetersLevel SensorsValves

Automation Logic

When

Trigger

A command is sent to a valve, relay, motor, or controller.

Default

Command acknowledgement is missing for 30 sec

Choices
Command acknowledgement is missing for10 sec30 sec60 secEnter value

Example: choose "Command acknowledgement is missing for" and keep the default 30 sec, select another preset, or enter another value.

If

Condition

The device does not confirm the expected result within the timeout.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Send an acknowledgement timeout alert.

Default

Notify me (warning)

Choices
Notify me (warning)Notify me (critical)

Example: choose "Notify me (warning)" for the default then behavior.

Active

Allowed Time

Use All day for commanded devices.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Valves, relays, pumps, and controllers where command confirmation matters.

Device Inputs

Gateways, Water Meters, Level Sensors, Valves

Output Behavior

Send an acknowledgement timeout alert.

Safety Note

Do not assume the field device changed state if acknowledgement is missing.

Test Method

Send a supervised command and confirm acknowledgement timing in normal operation.

Visual reference coming soon
Future screenshot area for the Command Ack Timeout setup screen and saved Smart card.
Command Ack Timeout Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Command Ack Timeout

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the notification or failsafe action happens when device communication changes.
  • Send a supervised command and confirm acknowledgement timing in normal operation.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.