Post-Close Flow Check

Configure Post-Close Flow Check in HPzenAi Smart. Detects flow after a valve should already be closed.

What it does

Detect water movement after a valve is closed.

Detects flow after a valve should already be closed. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryLeak & Flow
Works with
Water MetersValvesMotor Controllers

Automation Logic

When

Trigger

A valve close command completes.

Default

Flow continues after valve close for 60 sec

Choices
Flow continues after valve close for30 sec60 sec120 secEnter value

Example: choose "Flow continues after valve close for" and keep the default 60 sec, select another preset, or enter another value.

If

Condition

Flow continues after the allowed settling time.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Send an alert that water is still moving after closure.

Default

Notify me (critical)

Choices
Notify me (critical)Notify me (warning)

Example: choose "Notify me (critical)" for the default then behavior.

Active

Allowed Time

Use All day for shutoff verification.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Leak checks, stuck valve checks, and critical shutoff points.

Device Inputs

Water Meters, Valves, Motor Controllers

Output Behavior

Send an alert that water is still moving after closure.

Safety Note

Allow a short drain-down delay so normal pipe emptying does not trigger false alerts.

Test Method

Close the valve during supervised flow and confirm the meter reading drops as expected.

Visual reference coming soon
Future screenshot area for the Post-Close Flow Check setup screen and saved Smart card.
Post-Close Flow Check Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Post-Close Flow Check

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the alert or shutoff action happens when flow becomes unsafe.
  • Close the valve during supervised flow and confirm the meter reading drops as expected.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.