Motor & Energy

Maintenance Runtime

Configure Maintenance Runtime in HPzenAi Smart. Schedules service based on accumulated motor runtime.

What it does

Schedule service based on accumulated motor runtime.

Schedules service based on accumulated motor runtime. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryMotor & Energy
Works with
Motor ControllersEnergy MetersLevel Sensors

Automation Logic

When

Trigger

Runtime reaches the selected maintenance interval.

Default

Total runtime passes 500 h

Choices
Total runtime passes250 h500 h1000 hEnter value

Example: choose "Total runtime passes" and keep the default 500 h, select another preset, or enter another value.

If

Condition

Runtime tracking is enabled for the selected motor.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Send a maintenance reminder.

Default

Notify me (warning)

Choices
Notify me (warning)Notify me (info)

Example: choose "Notify me (warning)" for the default then behavior.

Active

Allowed Time

Use All day for continuous runtime tracking.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Pumps and motors with service intervals based on operating hours.

Device Inputs

Motor Controllers, Energy Meters, Level Sensors

Output Behavior

Send a maintenance reminder.

Safety Note

Reset or update the maintenance counter only after service is complete.

Test Method

Use a temporary low interval to confirm the reminder appears.

Visual reference coming soon
Future screenshot area for the Maintenance Runtime setup screen and saved Smart card.
Maintenance Runtime Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Maintenance Runtime

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the motor action or alert follows the selected protection condition.
  • Use a temporary low interval to confirm the reminder appears.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.