Motor & Energy

Overload Protection

Configure Overload Protection in HPzenAi Smart. Stops the motor before overload damage occurs.

What it does

Cut power before the motor burns out.

Stops the motor before overload damage occurs. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryMotor & Energy
Works with
Motor ControllersEnergy MetersLevel Sensors

Automation Logic

When

Trigger

Motor current exceeds the selected overload threshold.

Default

Motor current rises above 20 A

Choices
Motor current rises above15 A20 A30 AEnter value

Example: choose "Motor current rises above" and keep the default 20 A, select another preset, or enter another value.

If

Condition

The overload condition lasts longer than the configured delay.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Stop the motor and send a fault alert.

Default

Stop the motor and alert me

Choices
Stop the motor and alert meNotify me (critical)

Example: choose "Stop the motor and alert me" for the default then behavior.

Active

Allowed Time

Use All day for motor protection.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Pumps, fans, compressors, and motor loads monitored by HPzenAi controllers.

Device Inputs

Motor Controllers, Energy Meters, Level Sensors

Output Behavior

Stop the motor and send a fault alert.

Safety Note

Do not replace required electrical protection devices with app automation alone.

Test Method

Set thresholds from rated current and verify alerts without forcing unsafe overloads.

Visual reference coming soon
Future screenshot area for the Overload Protection setup screen and saved Smart card.
Overload Protection Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Overload Protection

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the motor action or alert follows the selected protection condition.
  • Set thresholds from rated current and verify alerts without forcing unsafe overloads.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.