Motor & Energy

Phase Loss Trip

Configure Phase Loss Trip in HPzenAi Smart. Trips a three-phase motor when any phase is missing.

What it does

Trip immediately if any phase is missing.

Trips a three-phase motor when any phase is missing. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryMotor & Energy
Works with
Motor ControllersEnergy MetersLevel Sensors

Automation Logic

When

Trigger

A phase-loss condition is detected.

Default

A phase is missing

Choices
A phase is missing

Example: choose "A phase is missing" for the default when behavior.

If

Condition

The motor is running or allowed to start and phase monitoring is active.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Stop or block the motor and send a phase-loss alert.

Default

Stop motor and alert me

Choices
Stop motor and alert meNotify me (critical)

Example: choose "Stop motor and alert me" for the default then behavior.

Active

Allowed Time

Use All day for three-phase motor protection.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Three-phase pumps, starters, and panels with phase monitoring.

Device Inputs

Motor Controllers, Energy Meters, Level Sensors

Output Behavior

Stop or block the motor and send a phase-loss alert.

Safety Note

Do not restart until the electrical supply issue is corrected.

Test Method

Verify phase readings during commissioning; do not intentionally remove a live phase for testing.

Visual reference coming soon
Future screenshot area for the Phase Loss Trip setup screen and saved Smart card.
Phase Loss Trip Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Phase Loss Trip

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the motor action or alert follows the selected protection condition.
  • Verify phase readings during commissioning; do not intentionally remove a live phase for testing.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.