Loading Guide

Preparing HPzenAi content

Skip to main content

Tank & Pump

Borewell Recharge Wait

Configure Borewell Recharge Wait in HPzenAi Smart. Gives a borewell or source tank time to recover before the next pumping attempt.

What it does

Pause pumping while the borewell recovers.

Gives a borewell or source tank time to recover before the next pumping attempt. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryTank & Pump
Works with
Level SensorsMotor ControllersGateways

Automation Logic

When

Trigger

The source runs low or dry-run protection stops the pump.

Default

Borewell level drops below 20%

Choices
Borewell level drops below10%20%30%Enter value

Example: choose "Borewell level drops below" and keep the default 20%, select another preset, or enter another value.

If

Condition

A retry is allowed and the configured recovery delay has not exceeded safe limits.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Pause pumping, wait for recovery, then allow the next controlled attempt.

Default

Stop the pump and retry after 60 min

Choices
Stop the pump and retry after30 min60 min120 minEnter valueStop the pump and notify meOnly notify me

Example: choose "Stop the pump and retry after" and keep the default 60 min, select another preset, or enter another value.

Active

Allowed Time

Use All day when the borewell is the primary water source.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Low-yield borewells and sites where short recovery waits improve water availability.

Device Inputs

Level Sensors, Motor Controllers, Gateways

Output Behavior

Pause pumping, wait for recovery, then allow the next controlled attempt.

Safety Note

Use conservative retry counts so the pump does not cycle repeatedly during a dry source condition.

Test Method

Trigger the recovery condition and confirm the pump waits for the configured interval before retrying.

Visual reference coming soon
Future screenshot area for the Borewell Recharge Wait setup screen and saved Smart card.
Borewell Recharge Wait Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Borewell Recharge Wait

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the pump starts and stops at the expected tank levels.
  • Trigger the recovery condition and confirm the pump waits for the configured interval before retrying.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.