Tank & Pump

Dry Sump Guard

Configure Dry Sump Guard in HPzenAi Smart. Protects the pump when the source sump runs low.

What it does

Never let the pump run on an empty sump.

Protects the pump when the source sump runs low. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryTank & Pump
Works with
Level SensorsMotor ControllersGateways

Automation Logic

When

Trigger

Sump level falls below the safe pumping point.

Default

Sump level drops below 15%

Choices
Sump level drops below10%15%20%Enter value

Example: choose "Sump level drops below" and keep the default 15%, select another preset, or enter another value.

If

Condition

The pump is running or about to start from another automation.

Default

Pump is running

Choices
Pump is runningNo condition

Example: choose "Pump is running" for the default if behavior.

Then

Action

Stop or block the pump command until the sump recovers.

Default

Stop the pump and alert me

Choices
Stop the pump and alert meStop the pumpOnly notify me

Example: choose "Stop the pump and alert me" for the default then behavior.

Active

Allowed Time

Use All day for pump protection.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Sump-fed overhead tank systems and borewell recharge tanks.

Device Inputs

Level Sensors, Motor Controllers, Gateways

Output Behavior

Stop or block the pump command until the sump recovers.

Safety Note

Set the safe pumping point above the pump inlet to account for turbulence and sensor movement.

Test Method

Simulate low sump level and confirm the pump stops or remains blocked.

Visual reference coming soon
Future screenshot area for the Dry Sump Guard setup screen and saved Smart card.
Dry Sump Guard Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Dry Sump Guard

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the pump starts and stops at the expected tank levels.
  • Simulate low sump level and confirm the pump stops or remains blocked.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.