Tank & Pump

Tank Low Alert

Configure Tank Low Alert in HPzenAi Smart. Notifies users before a tank reaches a critical low level.

What it does

Get notified before the tank runs dry.

Notifies users before a tank reaches a critical low level. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryTank & Pump
Works with
Level SensorsMotor ControllersGateways

Automation Logic

When

Trigger

Tank level drops below the selected low alert point.

Default

Tank level drops below 20%

Choices
Tank level drops below10%20%30%Enter value

Example: choose "Tank level drops below" and keep the default 20%, select another preset, or enter another value.

If

Condition

The tank reading is recent and the alert is enabled.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Send an alert so users can refill, inspect, or switch source before water runs out.

Default

Notify me (warning)

Choices
Notify me (warning)Notify me (critical)Notify me (info)

Example: choose "Notify me (warning)" for the default then behavior.

Active

Allowed Time

Use All day for water availability alerts.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Storage tanks that need user attention before automatic control is available.

Device Inputs

Level Sensors, Motor Controllers, Gateways

Output Behavior

Send an alert so users can refill, inspect, or switch source before water runs out.

Safety Note

Set the alert level early enough to leave time for manual action.

Test Method

Set a temporary alert threshold above the current level and confirm the notification is received.

Visual reference coming soon
Future screenshot area for the Tank Low Alert setup screen and saved Smart card.
Tank Low Alert Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Tank Low Alert

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the pump starts and stops at the expected tank levels.
  • Set a temporary alert threshold above the current level and confirm the notification is received.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.