Tank & Valve

Tank Inlet Valve

Configure Tank Inlet Valve in HPzenAi Smart. Controls tank filling through an inlet valve instead of direct pump switching.

What it does

Open the inlet valve when the tank needs water.

Controls tank filling through an inlet valve instead of direct pump switching. Use this automation when the selected field devices should work together without repeated manual setup.

CategoryTank & Valve
Works with
Level SensorsValvesRelay Controllers

Automation Logic

When

Trigger

Tank level falls below the selected refill point.

Default

Tank level drops below 30%

Choices
Tank level drops below20%30%40%Enter valueAt a scheduled timeChoose timeDailyWeekdaysWeekendsCustom days

Example: choose "Tank level drops below" and keep the default 30%, select another preset, or enter another value.

If

Condition

The inlet source is available and the valve is online.

Default

No condition

Choices
No condition

Example: leave No condition selected when the trigger alone should run the workflow.

Then

Action

Open the tank inlet valve until the tank reaches the stop level.

Default

Open the inlet valve until full

Choices
Open the inlet valve until fullOpen the inlet valve for30 min60 min120 minEnter valueOnly notify me

Example: choose "Open the inlet valve until full" for the default then behavior.

Active

Allowed Time

Use All day for utility-fed tanks or Day for planned filling periods.

Default

All day

Choices
All dayDay (6 AM - 6 PM)Night (6 PM - 6 AM)

Example: keep All day for protection workflows, or choose Day or Night when operation should stay inside site hours.

Automation Details

Recommended use

Gravity-fed tanks, municipal inlet control, and storage systems using motorized valves.

Device Inputs

Level Sensors, Valves, Relay Controllers

Output Behavior

Open the tank inlet valve until the tank reaches the stop level.

Safety Note

Keep overflow shutoff enabled for the same tank whenever possible.

Test Method

Trigger the low tank condition and confirm the inlet valve opens and later closes.

Visual reference coming soon
Future screenshot area for the Tank Inlet Valve setup screen and saved Smart card.
Tank Inlet Valve Walkthrough
Walkthrough video coming soon

Before You Start

Device Readiness

Link every device used by this workflow and confirm each one is online.

Device Selection

Choose the exact tank, pump, valve, relay, or meter that should be controlled.

Safe Test

Test with safe thresholds or manual observation before leaving the workflow enabled.

Guided Setup

Set Up Tank Inlet Valve

Step 1 / 12
9:41
1

Open the HPzenAi app.

Step 1 / 12

Commissioning Checks

  • Confirm the valve opens and closes at the expected tank condition.
  • Trigger the low tank condition and confirm the inlet valve opens and later closes.
  • Confirm the saved card shows the correct workflow, devices, schedule, and enabled state.
  • Review the event history after testing so the action is recorded as expected.
  • Keep safety-critical workflows active all day unless the site needs a specific time window.

Troubleshooting

  • If the Save button is disabled, complete every required trigger, condition, action, and timing field.
  • If the workflow does not run, confirm the devices are online and the active time allows it to run now.
  • If the action does not complete, check whether the target device is already in that state or cannot accept commands.
  • If notification behavior is missing, confirm phone notification permission and recent device data.